Sim2 HT5000 Manual do Utilizador Página 6

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 14
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 5
F1 BE EF 02 06 00 94 E6 5D 01 00 00 00 00
F2 BE EF 02 06 00 76 E7 5F 01 00 00 00 00
Info BE EF 02 06 00 A7 E6 5E 01 00 00 00 00
Auto BE EF 02 06 00 79 E2 60 01 00 00 00 00
Aspect BE EF 02 06 00 A8 E3 61 01 00 00 00 00
Aspect Normal BE EF 02 06 00 2A F4 83 01 00 00 00 00
Aspect Anamorphic BE EF 02 06 00 9D F5 84 01 00 00 00 00
Aspect Letterbox BE EF 02 06 00 4C F4 85 01 00 00 00 00
Aspect Panoramic BE EF 02 06 00 7F F4 86 01 00 00 00 00
Aspect Subtitle BE EF 02 06 00 62 F5 8B 01 00 00 00 00
Aspect Pixel to Pixel BE EF 02 06 00 AE F5 87 01 00 00 00 00
Aspect User 1 BE EF 02 06 00 51 F5 88 01 00 00 00 00
Aspect User 2 BE EF 02 06 00 80 F4 89 01 00 00 00 00
Aspect User 3 BE EF 02 06 00 B3 F4 8A 01 00 00 00 00
Notes:
1
When the unit is in Standby state, this command switches the unit on and the last source memorized
prior to switch off is automatically selected.
When the unit is On, this command displays the Source Selection window of the OSD.
2
When the unit is in Standby state, this command switches the unit on and the last source memorized
prior to switch off is automatically selected.
When the unit is On, and OSD is not displayed, this command selects the corresponding source.
3
When the unit is On, and OSD is not displayed, this command selects the corresponding source.
The response of the unit to a correct Remote Control Key Code consists of a single byte:
OK 06
Error 15
2.2 Operation Commands
The following codes provide direct access to SIM2 HT5000 User Interface operations not accessible via a
single Remote Control command. When an Operation Command is sent, OSD does not appear over the
picture.
Most of the following commands require a valid signal on the selected input. If the status of the input signal
is ‘No signal’ (see Section 2.3) they won’t be executed and an Error code will be sent back by the projector.
Only the following two commands are acknowledged and executed in a ‘No signal’ condition:
Lamp Power
Orientation
Brightness
Action Command Response
Increment BE EF 1A 0C 00 5E A3 00 00 02 00 00 00 00 00 00 00 00 00 OK 20 XX 00
Decrement BE EF 1A 0C 00 9B F2 00 00 03 00 00 00 00 00 00 00 00 00 Error 15
Get BE EF 1A 0C 00 51 53 00 00 01 00 00 00 00 00 00 00 00 00
XX is the hex representation of the value of Brightness.
Example: if the returned value is XX = 3C then Brightness value is 60.
6
Vista de página 5
1 2 3 4 5 6 7 8 9 10 11 12 13 14

Comentários a estes Manuais